LabeLase®
Non-Contact, Bar Code 
Printing Directly On Products



Features

  • Man-readable Identification, Logos, Standard Bar Codes
  • Local Terminal or Host Computer Interface
  • Label Hot or Cold Surfaces (Ambient to 1800° F)
  • Durable Abrasion Resistant
  • Resistant to Outdoor Environment
  • Label on Hot Glass and Ceramics Without Disturbing Structural Integrity
 

 

Overview

The LabeLase® Marking System offers a practical and cost effective alternative to manually stenciling products in an industrial environment. This system utilizes two of InfoSight's proven technologies to create a revolutionary marking solution. Using an ink spray nozzle to lay down a patch of white and then marking it with a high power CO2 laser, the LabeLase® system provides the ability to put a bar code, logo and man-readable characters directly on hot or ambient products without using a tag or label. The text and bar code data can be downloaded from a host computer or can be keyboard entered from the InfoSight standard terminal provided.

The LabeLase® Marking System can mark on various materials including ceramics, glass and metals. Structural integrity of the material is maintained during this marking application due to the non-contact marking. The only consumable is the ink that is sprayed as the initial step in the process. Major labor savings can be gained over hand stenciling. Consistent high quality bar codes and characters will help in meeting ISO9000 requirements. The equipment is robust enough to withstand any industrial situation.

 

System Options

  • Pre-programmed Library of Messages
  • Special Font Designs
  • Air Conditioning for Electronics Enclosure

 

Operator's Terminal

The operator's terminal is one method for entering messages to be printed by the LabeLase® Marking System. This terminal also displays system status information and is used to set system parameters and perform diagnostics.

 

 

Specifications

Power Requirements 117VAC, 60 Hz
Power Consumption 500 Watts
Air 60 psig @ 8 SCFM, Clean, Dry
Operator's Terminal
  • Display.......................................CRT
  • Input...........................................Alphanumeric keyboard
  • Interface......................................RS-232C
Host Interface
  • Electrical......................................RS-232C
  • Protocol.......................................InfoSight Standard Extended

 

Applications

Catalytic Converter

Automotive Bracket

Transmission Bell